Explanation of operation |
Switches on/off when the magnetic fields from the S pole and N pole of the magnet are applied alternately. This is principally applied in detection of revolution speed. |
Schematic operation drawing |
|
When the S pole of the magnet approaches the marked side of the Hall effect IC and the magnetic flux density exceeds Bop, Vout changes from H to L.
When the N pole of the magnet approaches the marked side of the Hall effect IC and the magnetic flux density exceeds Brp, Vout changes from L to H.
|
Product list(Continuous excitation type) The hall element in the 霍尔集成电路 is always driven. Operating ambient temperature range is -30 to 115°C. |
Supply Voltage (Vcc) Range |
Package Size (mm) |
Output H to L Magnetic Flux Density Operating Point (Bop) |
L |
W |
H |
High sensitivity 3 [mT] |
Low sensitivity 10 [mT] |
4.5 to 26.4 [V] (Typ. 12) |
4.4 |
3.6 |
1.2 |
|
|
3.1 |
3.0 |
1.0 |
|
3.0 |
4.1 |
1.15 |
|
4.5 to 18 [V] (Typ. 12) |
4.4 |
3.6 |
1.2 |
|
|
4.0 |
4.5 |
1.5 |
|
2.2 to 18 [V] (Typ. 12) |
4.4 |
3.6 |
1.2 |
|
|
3.1 |
3.0 |
1.0 |
|
3.0 |
4.1 |
1.15 |
|
2.5 to 5.5 [V] (Typ. 3) |
4.4 |
3.6 |
1.2 |
|
|
3.5 to 18 [V] (Typ. 12) |
2.1 |
2.1 |
0.55 |
|
|
|
|
Note: SMT - Package size includes the leads. SIP - Package size does not include the leads. |
Product list(With power-down function) The drive condition of the Hall element in the Hall effect IC (active power-down) can be adjusted from the outside. Operating ambient temperature is -30 to 85°C. |
Operating Voltage Range Supply Voltage (VDD) |
Package Size (mm) |
Output H to L Magnetic Flux Density Operating Point (Bop) |
L |
W |
H |
Typ. 1.8(Max. 4)[mT] |
1.6 to 5.5 [V] (Typ. 3) |
2.1 |
2.1 |
0.38 |
|
|
2.1 |
2.1 |
0.45 |
|
|
1.2 |
1.8 |
0.55 |
|
|
|
|